Search found 14 matches
- Tue Dec 20, 2022 3:35 pm
- Forum: General
- Topic: MGL Avionics Knowledgebase
- Replies: 2
- Views: 12276
Re: MGL Avionics Knowledgebase
Hi Adam, some possibilities i know of: -Wrong setting of sensor gain (pulses per gallon) -in case of engine installation with reflow line no return flow sensor (eg Rotax 914 has about 27gal/h fuel flow forward here) -sensor broken -bad sensor but for sure no issue to buying a plane ;-) best regards,...
- Sun Jun 05, 2022 8:43 am
- Forum: EFIS Systems
- Topic: Can RDAC 'share' sensors with steam gauges?
- Replies: 2
- Views: 3520
Re: Can RDAC 'share' sensors with steam gauges?
Depends on the steam gauges. the steam gauge Sensors depend on pulldown resistors. if the steam gauge has the same pulldown value as the MGL, it could be possible to read with the RDAC with PD/PU off so it just reads the voltage of the resistor pair VDO to sensor. If the resistor is different, you m...
- Mon Aug 30, 2021 9:29 pm
- Forum: EFIS Systems
- Topic: iEFIS ADS-B and FLARM in
- Replies: 2
- Views: 1634
Re: iEFIS ADS-B and FLARM in
Hello Rainier,
thanks for the hint, wasn't expecting 9600 for FLARM at all. tried from 19200 up.
thanks for the hint, wasn't expecting 9600 for FLARM at all. tried from 19200 up.
- Fri Aug 27, 2021 8:30 am
- Forum: EFIS Systems
- Topic: iEFIS ADS-B and FLARM in
- Replies: 2
- Views: 1634
iEFIS ADS-B and FLARM in
I have a nice setup with Discovery Lite and some additionals and self made devices (eg fake RDAC with calculation of values from primary RDAC's data). Everything is working as expected, just my FLARM and ADS-B Data stream is not shown. Data is NMEA from a TRX1500. I tried several BPS from the TRX an...