Is the sensor configured the same on both EFIS?
Both set for the same units (C or F)?
Search found 70 matches
- Sat Jul 30, 2022 5:37 am
- Forum: EFIS Systems
- Topic: Oil temp and pressure readings different on MX1 and EMS
- Replies: 2
- Views: 1198
- Thu Jul 14, 2022 6:24 pm
- Forum: General
- Topic: Fuel flow sensor fault
- Replies: 10
- Views: 17655
Re: Fuel flow sensor fault
I have struck a similar problem in the past, where a whitish waxy substance blocked up a fine mesh inline fuel filter. You could blow throught the filter OK while it was dry, but the moment it was wetted with fuel it blocked. It was apparently Durene- leaching from the inside of 2 new 20l fuel conta...
- Tue Jun 14, 2022 1:53 am
- Forum: EFIS Systems
- Topic: Programmable probe option not working???
- Replies: 3
- Views: 1362
Re: Programmable probe option not working???
I found another way to skin the cat.... The current input was not being used, so I configured it to behave as a GP 0-5V input. Zeroing current at sensor minimum and tweaking the current gain to give the desired full scale value at sensor maximum, you can use it as a GP analog input and link a displa...
- Mon Jun 13, 2022 6:18 pm
- Forum: EFIS Systems
- Topic: Programmable probe option not working???
- Replies: 3
- Views: 1362
Re: Programmable probe option not working???
That stuffs up my plans!
I had asumed it could also be configured as a general purpose 0-5V analog input using the programmable probe option to calibrate it.
Would be a nice option (hint!)
I had asumed it could also be configured as a general purpose 0-5V analog input using the programmable probe option to calibrate it.
Would be a nice option (hint!)
- Mon Jun 13, 2022 3:19 am
- Forum: EFIS Systems
- Topic: Programmable probe option not working???
- Replies: 3
- Views: 1362
Programmable probe option not working???
Hi Rainier- I think there is a problem using the programmable probe option- in the SIM at least (not tested yet in actual hardware) iEFIS G3 SIM V 1121 (fresh download) COOLANT channel set to programmable probe programmable probe set up in equal ascending steps 20C..160C between 1000..4000 ADC using...
- Sun Jun 05, 2022 7:41 pm
- Forum: EFIS Systems
- Topic: Empty black box on screen...won't go away.
- Replies: 2
- Views: 1333
Re: Empty black box on screen...won't go away.
That's a video input window.
The left or right curson buttons will scroll through video sources to none.
The left or right curson buttons will scroll through video sources to none.
- Fri May 20, 2022 6:31 pm
- Forum: MGL Radio frequency products
- Topic: MGL V6 VHF disable monitoring
- Replies: 2
- Views: 2051
Re: MGL V6 VHF disable monitoring
You can enable/disable scanning state at power up in the first level menu.
Page 17 of the manual.
Page 17 of the manual.
- Fri May 13, 2022 8:08 pm
- Forum: EFIS Systems
- Topic: Discovery Lite ASI
- Replies: 2
- Views: 1047
Re: Discovery Lite ASI
Trapped moisture slug in your pitot line?
- Sun May 08, 2022 8:11 pm
- Forum: General
- Topic: OAT wiring - testing?
- Replies: 6
- Views: 9277
Re: OAT wiring - testing?
Black to ground, red to input, pullup resisdtor ON, set sensor as LM335 type.
- Thu Apr 21, 2022 6:16 pm
- Forum: EFIS Systems
- Topic: Enigma Altitude
- Replies: 2
- Views: 996
Re: Enigma Altitude
Airspeed increasing as vacuum applied to the static makes sense- you are creating a positive differential pitot over static.
That also indicates the static sensor is working to some degree, as it is responding to pressure changes.
Try calibrating your altimteter channel.
That also indicates the static sensor is working to some degree, as it is responding to pressure changes.
Try calibrating your altimteter channel.