From an old post (11/01/2011 08:22) in MGLAvionicsUsers.org forum: This lag is created in the RDAC itself and is dependent on the number of pulses per RPM. The more pulses the more "immediate" the RPM indication. Extra lag however can be introduced if the RPM pulses are not consistent, in other word...
- Sun Sep 22, 2024 4:02 pm
- Forum: The MGL/Infinitec Singles
- Topic: Blaze AHR 4
- Replies: 4
- Views: 482
Re: Blaze AHR 4
Hello. You'll have to upgrade the AHRS-4 firmware. AHRS-4 Firmware Revision ======================== Version 1.08 25/05/2022 (Franz Lamers) -------------------------------------- Enhancement: Added a vertical card compass display https://www.mglavionics.co.za/Infinitec/Manuals/Blaze%20Firmware%20Rev...
- Sat Jun 29, 2024 2:30 pm
- Forum: EFIS Systems
- Topic: Raw values from level tank
- Replies: 5
- Views: 1847
Re: Raw values from level tank
Hello.
Disconnect the analog indicator. It is forcing about 6V to the RDAC FL input through it's internal resistor bridge