Search found 4 matches
- Sat Jan 25, 2025 1:27 pm
- Forum: EFIS Systems
- Topic: Iefis rpm not operational
- Replies: 2
- Views: 1740
Re: Iefis rpm not operational
Red cross on RPM display area indicates that RDAC data is not received. Check RDAC CAN connection, and check that RPM display field is assigned to correct RDAC number
- Mon Oct 07, 2024 6:59 am
- Forum: EFIS Systems
- Topic: MGL Odyssey G2 RPM reading delay
- Replies: 1
- Views: 1846
Re: MGL Odyssey G2 RPM reading delay
From an old post (11/01/2011 08:22) in MGLAvionicsUsers.org forum: This lag is created in the RDAC itself and is dependent on the number of pulses per RPM. The more pulses the more "immediate" the RPM indication. Extra lag however can be introduced if the RPM pulses are not consistent, in other word...
- Sun Sep 22, 2024 4:02 pm
- Forum: The MGL/Infinitec Singles
- Topic: Blaze AHR 4
- Replies: 4
- Views: 6842
Re: Blaze AHR 4
Hello. You'll have to upgrade the AHRS-4 firmware. AHRS-4 Firmware Revision ======================== Version 1.08 25/05/2022 (Franz Lamers) -------------------------------------- Enhancement: Added a vertical card compass display https://www.mglavionics.co.za/Infinitec/Manuals/Blaze%20Firmware%20Rev...
- Sat Jun 29, 2024 2:30 pm
- Forum: EFIS Systems
- Topic: Raw values from level tank
- Replies: 5
- Views: 6431
Re: Raw values from level tank
Hello.
Disconnect the analog indicator. It is forcing about 6V to the RDAC FL input through it's internal resistor bridge
Disconnect the analog indicator. It is forcing about 6V to the RDAC FL input through it's internal resistor bridge